3 Common Problems in Water Treatment Plants

3 min readInovar Engineering

Sewage treatment plants in India play a vital role in helping communities and businesses manage their water resources. STPs improve the availability of water and preserve the environment by removing pollutants from water. In sectors such as hotels, 49% of the water demand is for non-potable water used for cleaning and gardening activities. This can often be met with recycled water from the sewage treatment plant.

If a sewage treatment plant fails, it could have a serious impact on water availability for businesses, communities and the environment. A large number of sewage treatment plants in India tend to fail for simple reasons. If the common problems are addressed at an early stage, these plants could deliver consistent performance for decades.

1. Lack of air in the aeration system and overheating of blowers

What is the problem. The amount of oxygen in the tank is very low over a long period, and the blowers working to supply that oxygen overheat due to the increased load.

Why it occurs. This happens when the STP is receiving more pollutants than its capacity allows. It could be because the community or business that uses the STP has grown while the STP has not been upgraded. Another reason could be that the piping network and aeration system feeding the STP has become encrusted with pollutants over time.

What can be done. If the STP with this issue is old, acquiring a new plant with higher capacity is effective. However, retrofitting the STP with new technology and upgrades could significantly reduce your repair cost. If the pipes or aeration elements are encrusted, they should be cleaned.

If the amount of oxygen stays low in the long term, this can lead to deterioration of discharge parameters, foam formation on the surface and similar problems.

2. The downstream equipment fails

What is the problem. Waste such as plastic, paper or large non-biodegradable solids enters the downstream equipment, severely limiting its efficiency. Such materials block the pipes and cause wear and tear on other parts of the plant.

Why it occurs. The job of filtering large floating solids is done by the screening system. Often in places such as hotels or residential societies, the STPs are not started until a considerable amount of sewage has built up. In such cases, the screening system gets clogged. If the plant is not used regularly or is ill-maintained, parts of its screening system could break away during operation, letting large solids flow into the interior of the plant.

What can be done. Regular maintenance of the STP is key to maintaining the efficiency of the screening process. The equipment used in screening should be regularly cleaned by mechanical as well as manual means. Better quality screening systems could be deployed in consultation with the STP manufacturer.

3. Strong and widespread odour from the STP

What is the problem. The odour emanating from the sewage treatment plant can travel with the wind and become a serious issue for the community.

Why it occurs. Elements such as hydrogen sulphide, organic acids and mercaptans in the process water lead to strong odour. Hydrogen sulphide is generated by the bacteria present in process water. It is a colourless and extremely corrosive gas which could also lead to the failure of downstream equipment.

What can be done. There are two aspects to solving the odour problem. First, it is vital to identify and neutralize the source. Identifying the exact source requires a thorough analysis of the plant, and must be done in consultation with the plant manufacturer. Next, it is prudent to deploy effective odour-neutralization technology.

Inovar has developed highly effective odour-removal technology which can be deployed with STPs of any size and population capacity.

Published 02 June 2025 by Inovar Engineering.

Talk to our engineers

Have a plant that is not performing?

Send us your effluent characteristics and discharge norms. Our engineers will come back with a treatment scheme and an indicative footprint.

Contact our engineers

Call +91-7028039207

Blue pressure vessels with interconnecting pipework inside an industrial shed

Have a water or wastewater problem on site?

Tell us the site, the flow in KLD and what is going wrong. Our engineers will reply with a treatment scheme and an indicative footprint. Or call +91-7028039207.

Our solutions: STP plant · ETP plant · RO plant · ZLD plant